3.6 How can we estimate the required volume of filter media and space? - Humanitarian Sanitation Hub

3.6 How can we estimate the required volume of filter media and space?

Depending on the type of filter media, two formulas can be applied to determine the required volume and space of the filter system.

3.6.1 Filter media: Stone or Rocks

The NRC (National Research Council) formula for trickling-filter performance is an empirical expression developed by the National Research Council from an extensive study of the operating data of trickling treatment plants at military bases within the United States during World War II in the early 1940s.

It may be applied to single-stage and multi-stage rock filters with varying recirculation ratios.

The equation to calculate the BOD removal efficiency for a single-stage or first stage of a two-stage rock filter is:



Where,

ParameterDescriptionUnit
E1Efficiency of BOD removal for
the first stage at 20°C
%
OLOrganic load BODkg/d
VVolume of the filter media m3
FRecirculation factor

To calculate the BOD removal efficiency for the second filter in a two-stage rock filter, the following formula is used:



Where,

ParameterDescriptionUnit
E2Efficiency of BOD removal for a
second-stage filter at 20°C
%
OL’Organic load BOD applied to
the second-stage filter
kg/d

The recirculation factor (F) is calculated by: (If no recirculation is planned, then F = 1)



Where,

ParameterDescriptionUnit
FRecirculation factor
rRecirculation ratioQR/Q
QRRecirculation flowm3/d
QInfluent flowm3/d

The overall BOD removal efficiency of a two-stage filter system can be computed by



BOD removal efficiency in the biological treatment process is significantly influenced by wastewater temperature. Warmer temperatures generally enhance microbial activity, leading to more effective degradation of pollutants.

The effect of temperature can be calculated as



Exercise

Let us practice and apply the formula to determine the size of the trickling filter.

Determine the size of the single-stage trickling filter, without recirculation using the NRC equations. The assumption is as follows:


ParameterDescriptionValueUnit
TInfluent temperature20°C
QinInfluent flow100m3/d
CinBOD5 influent 150mg/L
CoutBOD5 effluent 30mg/L
DFilter depth 1.5m
FRecirculation factor1

Step 1: Determine the overall required removal efficiency (E)



Step 2: Calculate Organic Load BOD in kg/d (OL)



Be mindful of unit adjustments:



Step 3: Calculate the volume of the filter (V)




Step 4: Calculate the area of the rectangular filter (A)



Step 5: Cross-check if our result would also be within the suggested ranges for the Organic Loading Rate (0.08 – 0.22 kgBOD/m3/d) and Hydraulic Loading Rate (1 – 4 m3/m2/d)



The organic loading rate exceeds the recommended limits; therefore, the volume must be adjusted accordingly.


Step 5.1: Adjust the required filter volume. Defining an intended organic loading rate of 0.18 kgBOD/m3/d, the following volume is required:


Step 5.2: Adjust the required filter area.


3.6.2 Filter media: Plastic

1966 Germain applied the Schulze formulation to a plastic media trickling filter and proposed the following equation.



Where,

ParameterDescriptionUnit
StBOD5 effluentmg/L
S0BOD5 influentmg/L
eEuler number, a mathematical constant (e = 2.71828)
kEmpirical reaction rate
(Schulze determined the value of k to be 0.69/d, at 20°C for plastic media)
d-1
DFilter depthm
HLRHydraulic loading ratem3/m2d
nEmpirical constant of the filter media
(Schulze determined the value of n = 0.67 for plastic media)

Please note that the value of k in these equations depends upon temperatures of 20°C. Therefore, a correction factor to any other temperature needs to be applied and is as follows:



Where,

ParameterDescriptionUnit
kTReaction rate at the desired temperatured-1
0Temperature correction coefficient, usually assumed to be 1.035
k20Reaction rate at 20°Cd-1
TTemperature at which the value of k is desired°C

Exercise

Let us practice and apply the formula and determine the size of the trickling filter.

The assumptions are as follows:


ParameterDescriptionValue in ExerciseUnit
TInfluent temperature25°C
QinInfluent flow100m3/d
CinBOD5 influent 150mg/L
Cout (= St)BOD5 effluent 30mg/L
DFilter depth 4.5m
rRecirculation ratio2
k20Reaction rate at 20°C0.69d-1
nEmpirical constant of the filter media (Plastic) 0.67 

Step 1: Adjust reaction rate k according to the temperature.



Step 2: Calculate BOD5 influent after recirculation of the wastewater (S0).



Step 3: Calculate the Hydraulic Loading Rate (HLR) based on the BOD5 influent after recirculation of the wastewater.



Step 4: Calculate the required filter area (A).


Total Inflow to the filter, Qtotal :



Area of the filter, A :



Even in the scenario where wastewater is recirculated within the system twice, the area of the trickling filter with plastic media (33.37 m2) is smaller compared to the rock media (55.55 m2).

x
News