Emergency Sanitation - Developing Criteria for Pit Latrine Lining

Author: Reed, B., Torr, D., Scott, R.

Year: 2016

Publisher: WEDC, Loughborough, UK

Pit latrine linings for emergency sanitation facilities require different performance criteria from those for pits used in longer-term development work. Various international initiatives are currently under way to develop new methods of supporting the pits used for latrines in emergencies, but before a solution can be found, the problem needs to be defined. Current field guidance lacks the level of detail required by humanitarian workers to construct durable pits in a timely manner. Consultations with international humanitarian field staff and UK-based geotechnical engineers were used in this research project to identify design, construction, and operational requirements of emergency pit-lining systems. However, rather than closely defined performance requirements, the study identified a wide range of criteria that need to be considered and clear distinctions between emergency and longer-term solutions. Latrines constructed in the initial stages of emergencies are likely to be communal, with long rectangular pits that require frequent emptying. Current knowledge of suitable pit support methods is sufficient to provide a limited range of standard designs that could be selected to meet local requirements.

Still have questions?

You could not find the information you were looking for? Please contact our helpdesk team of experts for direct and individual support.